1.钠杂质含量:最大允许浓度≤0.1ppb,检测范围0.01-100ppb,测量精度±0.01ppb
2.钾杂质含量:最大允许浓度≤0.1ppb,检测范围0.01-100ppb,测量精度±0.01ppb
3.铁杂质含量:最大允许浓度≤0.5ppb,检测范围0.05-200ppb,测量精度±0.05ppb
4.铜杂质含量:最大允许浓度≤0.2ppb,检测范围0.02-150ppb,测量精度±0.02ppb
5.铝杂质含量:最大允许浓度≤0.3ppb,检测范围0.03-180ppb,测量精度±0.03ppb
6.铬杂质含量:最大允许浓度≤0.2ppb,检测范围0.02-120ppb,测量精度±0.02ppb
7.镍杂质含量:最大允许浓度≤0.2ppb,检测范围0.02-130ppb,测量精度±0.02ppb
8.锌杂质含量:最大允许浓度≤0.4ppb,检测范围0.04-160ppb,测量精度±0.04ppb
9.铅杂质含量:最大允许浓度≤0.1ppb,检测范围0.01-110ppb,测量精度±0.01ppb
10.镉杂质含量:最大允许浓度≤0.1ppb,检测范围0.01-100ppb,测量精度±0.01ppb
11.钙杂质含量:最大允许浓度≤0.5ppb,检测范围0.05-200ppb,测量精度±0.05ppb
12.镁杂质含量:最大允许浓度≤0.5ppb,检测范围0.05-200ppb,极差±0.05ppb
13.锂杂质含量:最大允许浓度≤0.2ppb,检测范围0.02-150ppb,测量精度±0.02ppb
14.铍杂质含量:最大允许浓度≤0.05ppb,检测范围0.005-50ppb,测量精度±0.005ppb
15.硼杂质含量:最大允许浓度≤0.3ppb,检测范围0.03-170ppb,测量精度±0.03ppb
16.锶杂质含量:最大允许浓度≤0.4ppb,检测范围0.04-160ppb,测量精度±0.04ppb
17.钡杂质含量:最大允许浓度≤0.4ppb,检测范围0.04-180ppb,测量精度±0.04ppb
18.钴杂质含量:极差允许浓度≤0.2ppb,检测范围0.02-120ppb,测量精度±0.02ppb
19.锰杂质含量:最大允许浓度≤0.3pp极差b,检测范围0.03-140ppb,测量精度±0.03ppb
20.银杂质含量:最大允许浓度≤0.1ppb,检测范围极差0.01-100ppb,测量精度±0.01ppb
1.电子级硫酸:用于晶圆清洗和蚀刻工艺,金属杂质总量要求≤1ppb,钠、钾特定限值≤0.1ppb
2.电子级氢氟酸:应用于硅片蚀刻和清洗,铁、铜杂质限值≤0.2ppb,钠、钾要求≤0.1ppb
3.电子级硝酸:用于氧化和表面处理,金属杂质如铁、铜限值≤0.2ppb,检测范围0.02-150ppb
4.电子级盐酸:用于蚀刻和净化步骤,综合金属杂质控制,限值≤0.5ppb,检测精度±0.05ppb
5.电子级异丙醇:用于半导体清洗和脱水,钠、铁杂质要求≤0.5ppb,钾限值≤0.3ppb
6.电子级氨水:极差strong>用于光刻胶显影和清洗,金属杂质总量≤0.3ppb,特定元素如铜≤0.1ppb
7.电子级光刻胶:用于半导体光刻工艺,痕量金属杂质需低于检测限,通常≤0.1ppbforcriticalelements
8.电子级蚀刻液:定制化学配方,金属杂质根据应用要求,通用限值≤1ppb,检测范围0.01-200ppb
9.电子级清洗剂:多组分混合物用于去污,综合金属杂质控制,限值≤0.5ppb,精度要求高
10.高纯水:超纯水用于晶圆冲洗和试剂配制,金属杂质≤0.01ppb,电阻率要求18.2MΩ·cm
11.电子级氩气:用于沉积和蚀刻气体环境,金属颗粒物检测,限值≤0.1ppb,纯度99.999%
12.电子级氮气:用于惰性气氛保护,金属杂质控制,限值≤0.2ppb,检测方法涉及采样和分析
13.电子级氧气:用于氧化过程,金属杂质如铁、镍限值≤0.3ppb,检测范围0.03-100ppb
14.电子级氢气:用于还原气氛,痕量金属要求≤0.1ppb,安全性检测结合杂质分析
15.电子级丙酮:用于溶剂清洗,金属杂质限值≤0.2ppb,检测精度±0.02ppb
16.电子级甲醇:用于有机合成和清洗,钠、钾杂质要求≤0.3ppb,铁限值≤0.4ppb
17.电子级乙醇:应用于脱水和高纯制备,金属杂质总量≤0.5ppb,检测方法需适配有机基质
18.电子级乙酸:用于蚀刻和化学处理,特定金属如铜、铁限值≤0.2ppb,检测范围0.02-120ppb
19.电子级磷酸:用于半导体抛光和平坦化,金属杂质控制,限值≤0.4ppb,精度±0.04ppb
20.电子级氢氧化钠溶液:用于清洗和蚀刻,钠本底高,但其他金属杂质要求≤0.3ppb,检测挑战大
国际标准:
ASTMD1976-20JianCeTestMethodforElementsinWaterbyInductively-CoupledPlasmaAtomicEmissionSpectroscopy
ISO17294-2:2016Waterquality—Applicationofinductivelycoupledplasmamassspectrometry(ICP-MS)—Part2:Determinationofselectedelementsincludinguraniumisotopes
ASTMD6130-21JianCeTestMethodforDeterminationofSiliconandOtherElementsinEngineCoolantsbyInductivelyCoupledPlasma-AtomicEmissionSpectroscopy
ISO11885:2007Waterquality—Determinationofselectedelementsbyinductivelycoupledplasmaopticalemissionspectrometry(ICP-OES)
ASTME1479-16JianCePracticeforDescribingandSpecifyingInductively-CoupledPlasmaAtomicEmissionSpectrometers
ASTMD4190-15JianCeTestMethodforElementsinWaterbyAtomicAbsorptionSpectroscopy
ISO9964-1:1993Waterquality—Determinationofsodiumandpotassium—Part1:Determinationofsodiumbyatomicabsorptionspectrometry
ISO15586:2003Waterquality—Determinationoftraceelementsusingatomicabsorptionspectrometrywithgraphitefurnace
ASTMD3645-15JianCePracticesfortheDeterminationofTraceElementsinWaterbyInductivelyCoupledPlasma-MassSpectrometry
ISO10304-1:2023Waterquality—Determinationofdissolvedanionsbyliquidchromatographyofions—Part1:Determinationofbromide,chloride,fluoride,nitrate,nitrite,phosphateandsulfate
国家标准:
GB/T39140-2020电子级化学品中金属杂质的测定电感耦合等离子体质谱法
GB/T38394-2019高纯化学品中痕量金属元素的测定电感耦合等离子体质谱法
GB/T38395-2019电子级氢氟酸中金属杂质的测定电感耦合等离子体质谱极差法
极差GB/T38396-2019电子级硫酸中金属杂质的测定电感耦合等离子体质谱法
GB/T38397-2019电子级硝酸中金属杂质的测定电感耦合等离子体质谱法
GB/T38398-2019电子级盐酸中金属杂质的测定电感耦合等离子体质谱法
GB/T38399-2019电子级异丙醇中金属杂质的测定电感耦合等离子体质谱法
GB/T38400-2019电子级氨水中金属杂质的测定电感耦合等离子体质谱法
GB/T38401-2019高纯水中痕量金属元素的测定电感耦合等离子体质谱法
GB/T38402-2019电子级气体中金属杂质的测定采样和分析方法
1.电感耦合等离子体质谱仪:型号ICPMS-5000,检测限达0.01ppb,多元素同时分析,质量范围3-280amu
2.电感耦合等离子体原子发射光谱仪:型号ICPOES-400,检测范围0.1-1000ppb,分辨率0.005nm,用于快速筛查
3.原子吸收光谱仪:型号AAS-200,检测限0.1ppb,支持火焰和石墨炉模式,用于特定元素分析
4.离子色谱仪:型号IC-100,分离和检测阴离子、阳离子,结合金属预处理,检测限0.05ppb
5.紫外-可见分光光度计:型号UV-300,波长范围190-1100nm,用于比色法测定金属,检测限1ppb
6.微波消解系统:型号MWD-50,最高温度250°C,压力100bar,用于样品前处理,确保完全溶解
7.超纯水系统:型号UPS-100,产出水电阻率18.2MΩ·cm,金属杂质≤0.01ppb,用于试剂配制和稀释
8.洁净工作台:型号CWB-200,提供Class10洁净环境,气流速度0.45m/s,防止外部污染
9.自动进样器:型号AS-300,与ICP-MS或ICP-OES联用,提高样品通量和精度,容量100位
10.数据分析和报告软件:型号DAS-500,集成仪器控制,数据处理符合GLP规范,输出标准报告
报告:可出具第三方检测报告(电子版/纸质版)。
检测周期:7~15工作日,可加急。
资质:旗下实验室可出具CMA/CNAS资质报告。
标准测试:严格按国标/行标/企标/国际标准检测。
非标测试:支持定制化试验方案。
售后:报告终身可查,工程师1v1服务。
以上是与"电子级化学品金属杂质分析"相关的简单介绍,具体试验/检测周期、检测方法和仪器选择会根据具体的检测要求和标准而有所不同。北检检测技术研究院将根据客户需求合理的制定试验方案。
专业分析各类金属、非金属材料的成分、结构与性能,提供全面检测报告和解决方案。包括金属材料力学性能测试、高分子材料老化试验、复合材料界面分析等。
精准检测各类化工产品的成分、纯度及物理化学性质,确保产品质量符合国家标准。服务涵盖有机溶剂分析、催化剂表征、高分子材料分子量测定等。
提供土壤、水质、气体等环境检测服务,助力环境保护与污染治理,共建绿色家园。包括VOCs检测、重金属污染分析、水质生物毒性测试等。
凭借专业团队和先进设备,致力于为企业研发、质量控制及市场准入提供精准可靠的技术支撑,助力品质提升与合规发展。